Pure Ti · PEM Grade

Titanium Fiber Felt

Sintered pure titanium fiber felt — primary specification is the porous transport layer (PTL) in PEM water electrolyzers. Porosity 40–80% (60–70% standard), pore size 5–80 µm.

40–80%Porosity
5–80 µmPore size range
300 °CMax operating temp
≥99%Filtration efficiency
Mesh & Sheet

Titanium Fiber Felt

Manufactured from pure titanium fiber (≥99.5% Ti, fiber diameter 20–40 µm) by random fiber laying, pressing, and vacuum sintering into a rigid felt sheet. Porosity 40–80% (60–70% standard); pore size 5–80 µm by specification. Standard sheet size up to 1200 × 1200 mm, custom on request.
Material
Pure Titanium ≥99.5%
Fiber diameter
20 – 40 µm
Porosity
40 – 80% (60 – 70% standard)
Pore size
5 – 80 µm (by specification)
Thickness
0.1 – 6 mm (single or multi-layer)
Sheet size
Up to 1200 × 1200 mm, custom
Standard
GB/T 20100-2006

The primary market is PEM water electrolysis. Titanium fiber felt is one option for a PEM anode porous transport layer (PTL). Confirm suitability for the cell design, contact resistance, coating requirements and operating conditions; it is not the only available PTL structure. FILTURE supplies single-layer felt and multi-layer felt assemblies in thicknesses from 0.1 mm to 6 mm, cut to cell dimensions or in sheet rolls up to 1200 × 1200 mm for customer die-cutting.

For fuel-cell applications, coatings or bonded composites, submit the drawing and operating conditions for review. Availability, dimensions, treatment specification and application suitability require written confirmation before quotation or ordering; these are not confirmed standard supply options.

Secondary applications include pharmaceutical clarification, food processing, and high-temperature gas filtration, where the high void volume (40–80%, 60–70% standard) gives low pressure drop at high flow rates and good dirt-holding capacity.

Technical Specifications

Titanium Fiber Felt — Full Specification

Properties & Performance
Material
Pure Ti ≥99.5%
Fiber diameter
20 – 40 µm
Porosity
40 – 80% (60 – 70% standard)
Pore size
5 – 80 µm
Permeability
350 – 450 L/(m²·s)
Max pressure
3.0 MPa
Max temperature
300 °C
Filtration eff.
≥ 99%
Tensile strength
≥ 20 N/mm²
Standard
GB/T 20100-2006
Dimensions & Configuration
Thickness
0.1 – 6 mm per layer
Layers
Single or multi-layer assemblies
Sheet size
Roll or cut to cell dimensions, up to 1200 × 1200 mm
Chem. resistance
Compatibility review required
Cleaning
Ultrasonic; solvent soak
Form
Cut-to-dimension or sheet roll
Custom
Thickness, porosity, pore size to spec
Surface treatment
Subject to written technical and supply confirmation
Composite option
Subject to written technical and supply confirmation
Product Features

What Makes Titanium Fiber Felt Reliable

PEM Anode PTL Selection

Titanium fiber felt is one option for a PEM anode porous transport layer (PTL). Confirm suitability for the cell design, contact resistance, coating requirements and operating conditions; it is not the only available PTL structure.

40–80% Porosity

High void volume enables simultaneous electron conduction, water ingress to membrane, and oxygen escape — the competing mass transfer requirements of the PEM anode PTL.

Pore Size and Thickness by Specification

Pore size 5–80 µm, thickness 0.1–6 mm — specified to the individual cell design. Multi-layer assemblies for gradient porosity structures on request.

Material Compatibility

Confirm material compatibility for the actual medium, concentration, temperature and operating conditions before ordering. Titanium is not specified here as universally resistant to hydrochloric or sulfuric acid.

Surface Treatment Review

Specify the intended surface treatment and its purpose. Coating availability, loading, conductivity, wettability and effects on porosity must be reviewed and confirmed; no standard platinum or PTFE treatment is promised here.

Composite Design Review

Submit the proposed layer structure, dimensions and joining requirements. Feasibility, supply capability and application performance must be confirmed; a diffusion-bonded felt-plate composite is not a confirmed standard offering.

Applications

Where Titanium Fiber Felt Is Specified

PEM Water Electrolyzer — Anode PTL

Porous transport layer on the anode side of a PEM water electrolyzer. It supports water supply, oxygen removal and electrical contact with the adjacent cell components. Suitability depends on the cell design and operating conditions.

0.3–2 mm thick · Custom cell dims · Ti

PEM Fuel Cell — Anode Side

Gas diffusion medium in hydrogen fuel cell anodes. Ti felt used in applications where high corrosion resistance is needed.

Custom thickness · 20–40 µm fiber

Fuel Cell Application Review

Fuel-cell use requires evaluation of the electrode environment, operating temperature, surface treatment and contact resistance. Suitability as a cathode gas diffusion layer and supply specifications are not confirmed and require application-specific validation.

Subject to written technical and supply confirmation

Composite Design Review

Submit the proposed layer structure, dimensions and joining requirements. Feasibility, supply capability and application performance must be confirmed; a diffusion-bonded felt-plate composite is not a confirmed standard offering.

Subject to written technical and supply confirmation

Alkaline Electrolyzer Components

Ti fiber felt for electrode and separator support in alkaline electrolyzers — stable in KOH electrolyte at elevated temperature.

KOH-compatible · 1–5 mm · Custom

Pharmaceutical Clarification

Sintering joins the metal fibers. Particle and fiber release must be assessed under the specified operating, cleaning and backwash conditions; no zero-shedding guarantee is made.

5–50 µm · Ti

Food and Beverage Filtration

Pharmaceutical and food-contact suitability must be assessed for the finished component and intended use. Material grade alone does not establish biocompatibility or regulatory compliance; agree the required evidence before ordering.

5–50 µm · Application validation required

High-Temperature Gas Filtration

High-porosity Ti felt for hot-gas filtration where the 300 °C rating and chemical resistance of titanium are needed.

5–80 µm · 300 °C · Compatibility review required

Specify Your PTL or Filtration Requirements

Provide cell dimensions, required porosity, pore size, and layer thickness. We'll confirm availability and include permeability data with the quotation.

FILTURE is a supplier and exporter of sintered metal filter elements — parts are made to order and shipped worldwide.